Lubricants Catalog

801 Products
HYDRANSAFE HFA S5 visual
HYDRANSAFE HFA S5

Hot pressing machines and systems specially designed for low-viscosity aqueous fl uids. Operating temperatures: +5 °C to +55 °C.

HYDRANSAFE HFC 146 visual
HYDRANSAFE HFC 146

HYDRANSAFE HFC 146 is a high performance synthetic water-polymer, fireresistant hydraulic fluid. Regulation and hydraulic circuits of Furnaces, Continuous Casting Units in the Steel and Aluminium Industry, Heat-treat Ovens for quenching operations, Drying Furnace and other applications in fire risk areas, as in mining industry… Hydraulic systems of mould injection machines.

HYDRANSAFE HFC-E 46 visual
HYDRANSAFE HFC-E 46

Fire resistant and biodegradable water based hydraulic fluid (HFC-E type) boosted in antiwear and anti corrosion additives to match mineral based performances on pump tests.

HYDRANSAFE HFC-E 68 visual
HYDRANSAFE HFC-E 68

- HYDRANSAFE HFC-E 68 is a non flammable hydraulic fluid, falling under the HFC-E classification, developed to replace standard mineral oils with equal equipment protection. It provides highly advanced fire risk management without compromising mechanical performances. - HYDRANSAFE HFC-E 68, unlike standard water based products, is fortified in innovative antiwear additives to pass the most stringent pump tests. Results on Vickers pumps wear test exhibits a wear as low as 4 mg on ring and valves combined when the limit is 180mg for the ring and 50mg for the valves. - HYDRANSAFE HFC-E 68 is designed to work on all kind of hydraulics pumps in various conditions, in mobile and stationary equipment.

HYDRANSAFE HFDU 46 visual
HYDRANSAFE HFDU 46

Recommended in the event of incidental leaks into the environment. Operating temperature: -10 °C to +70 °C on a continuous basis, +120 °C at peak periods.

HYDRANSAFE HFDU 68 visual
HYDRANSAFE HFDU 68

Recommended in the event of incidental leaks into the environment. Operating temperature: -10 °C to +70 °C on a continuous basis, +120 °C at peak periods.

HYDRANSAFE HFDU LC 168 visual
HYDRANSAFE HFDU LC 168

Recommended in the event of incidental leaks into the environment. Operating temperature: -10 °C to +70 °C on a continuous basis, +120 °C at peak periods.

HYDROFLO CT visual
HYDROFLO CT

​Hydraulic fluid with very high viscosity index & shear resistance for severe conditions

ISOVOLTINE BIO visual
ISOVOLTINE BIO

Fire resistant and biodegradable transformer oil based on synthetic esters

ISOVOLTINE BIO VE visual
ISOVOLTINE BIO VE

Fire resistant and biodegradable transformer oil based on natural esters

ISOVOLTINE II visual
ISOVOLTINE II

Naphthenic mineral transformer oil compliant with IEC 60296, Uninhibted

ISOVOLTINE II X visual
ISOVOLTINE II X

Naphthenic mineral transformer oil compliant with IEC 60296, Inhibited

Personal Data and CookiesGeneral Condition of UseLubricants Catalog © 2025 TotalEnergies Lubricants